  • A 3-phase Contactor suitable for various applications such as Motor starting, Isolation, By-pass and Distribution application up to max 690 V


  • Specifications

  • Number of Main Contacts NO: 3
  • Number of Main Contacts NC: 0
  • Number of Auxiliary Contacts NO: 1
  • Number of Auxiliary Contacts NC: 1
  • Rated Operational Voltage: Main Circuit 690 V
  • Rated Frequency (f): Main Circuit 50/60 Hz
  • Conventional Free-air Thermal Current (Ith): acc. to IEC 60947-4-1, Open Contactors q = 40 °C 400 A
  • Rated Operational Current AC-1 (Ie): (690 V) 40 °C 400 A
  • (690 V) 55 °C 350 A
  • (690 V) 70 °C 290 A
  • Rated Operational Current AC-3 (Ie): (220 / 230 / 240 V) 55 °C 260 A
  • (380 / 400 V) 55 °C 260 A
  • (415 V) 55 °C 260 A
  • (440 V) 55 °C 240 A
  • (500 V) 55 °C 240 A
  • (690 V) 55 °C 220 A
  • Rated Operational Power AC-3 (Pe): (220 / 230 / 240 V) 80 KWT
  • (380 / 400 V) 140 KWT
  • (415 V) 140 KWT
  • (440 V) 140 KWT
  • (500 V) 180 KWT
  • (690 V) 200 KWT
  • Rated Breaking Capacity AC-3 acc. to IEC 60947-4-1: 8 x Ie AC-3
  • Rated Making Capacity AC-3 acc. to IEC 60947-4-1: 10 x Ie AC-3
  • Short-Circuit Protective Devices: gG Type Fuses 500 A
  • Rated Short-time Withstand Current (Icw): at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 2400 A
  • at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 500 A
  • at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 1100 A
  • at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 3500 A
  • at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 1500 A
  • Maximum Breaking Capacity: cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 2600 A
  • cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 2400 A
  • Maximum Electrical Switching Frequency: AC-1 300 cycles per hour
  • AC-2 / AC-4 150 cycles per hour
  • AC-3 300 cycles per hour
  • Rated Operational Current DC-1 (Ie): (110 V) 2 Poles in Series, 40 °C 400 A
  • (220 V) 3 Poles in Series, 40 °C 400 A
  • Rated Operational Current DC-3 (Ie): (110 V) 2 Poles in Series, 40 °C 400 A
  • (220 V) 3 Poles in Series, 40 °C 400 A
  • Rated Operational Current DC-5 (Ie): (110 V) 2 Poles in Series, 40 °C 400 A
  • (220 V) 3 Poles in Series, 40 °C 400 A
  • Rated Insulation Voltage (Ui): acc. to UL/CSA 600 V
  • acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V
  • Rated Impulse Withstand Voltage (Uimp): Main Circuit 8 kV
  • Mechanical Durability: 5 million
  • Maximum Mechanical Switching Frequency: 3600 cycles per hour
  • Coil Operating Limits: (acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C)
  • Rated Control Circuit Voltage (Uc): 50 Hz 110 V
  • 60 Hz 110 ... 120 V
  • Coil Consumption: Holding at Max. Rated Control Circuit Voltage 50 Hz 60 V·A
  • Holding at Max. Rated Control Circuit Voltage 60 Hz 65 V·A
  • Pull-in at Max. Rated Control Circuit Voltage 50 Hz 1350 V·A
  • Pull-in at Max. Rated Control Circuit Voltage 60 Hz 1550 V·A
  • Operate Time: Between Coil De-energization and NC Contact Closing 7 ... 13 ms
  • Between Coil De-energization and NO Contact Opening 10 ... 16 ms
  • Between Coil Energization and NC Contact Opening 12 ... 30 ms
  • Between Coil Energization and NO Contact Closing 17 ... 35 ms
  • Connecting Capacity Main Circuit: Bar 32 mm
  • Rigid Al-Cable 2 x 95 ... 120 m²
  • Rigid Cu-Cable 16 ... 240 m²
  • Connecting Capacity Auxiliary Circuit: Flexible with Ferrule 2x 0.75 ... 2.5
  • Flexible with Insulated Ferrule 1x 0.75 ... 2.5
  • Flexible 2x0.75 ... 2.5 m²
  • Solid 1 x 1 ... 4 m²
  • Stranded 2 x 1 .... 4 m²
  • Degree of Protection: acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
  • acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
  • Connecting Terminals (delivered in open position) Main Poles: Flat type c/w screws and bolts
  • Terminal Type: Main Circuit: Bars
  • Dimensions
  • Product Net Width: 140 mm
  • Product Net Depth / Length: 180.5 mm
  • Product Net Height: 227 mm
  • Product Net Weight: 5.4 kg
  • Minimum sell quantity:

    Order Quantity Multiple:

    Technical Specifications