Skip to content Skip to navigation menu
click to open Expanded view
Schneider Electric Schneider Electric (View All Products)

Schneider Electric Actassi ACTTG4P6ASCM3RBU Cable - Category 6A - CM - FTP - 10G - 305m - Blue

  • Schneider Electric
  • BW#: 00707221
  • Mfr#: ACTTG4P6ASCM3RBU
  • UNSPSC#: 43223303
Login or Register to view price
QTY

Features
  • RJ45 Connectors for Cat 5e, Cat 6 and Cat 6A performance
  • Patch panels
  • Copper and fiber optic LAN cables
  • Patch cords and connecting hardware
  • Cabling and server enclosures
  • Intelligent Solutions
  • Pre-terminated Copper and Pre-terminated Fiber (MTP) solutions
  • One solution provider, giving seamless end-to-end connectivity for buildings and data centres
  • Comprehensive product offer; connectors, LAN cables, patch cords, panels, enclosures.
  • Designed to perfectly fit to other Schneider Electric products and solutions
  • Part of TOP - the Schneider Electric Total Office Performance system for buildings
  • Easy to specify, easy to install, easy to use and easy to upgrade
  • Future-proof - no problems with retro-fitting
  • Performance exceeding international standards
  • Construction Product Regulation (CPR) compliance products are available since July-2017; copper cable, fiber cable and preterm optics links
  • Software tools to facilitate the design of complete infrastructures


  • Specifications

  • Range: Actassi
  • Product or component type: Copper cable
  • Colour Tint: Blue
  • Cable shielding type: FTP
  • Ambient Air Temperature For Operation : 75-75 °C
  • Conductor Material : Solid Bare Copper
  • Power Sum Alien Near-End Crosstalk [Psanext] : 67 Db At 1 Mhz
  • 67 Db At 4 Mhz
  • 67 Db At 8 Mhz
  • 67 Db At 10 Mhz
  • 67 Db At 16 Mhz
  • 67 Db At 20 Mhz
  • 67 Db At 25 Mhz
  • 67 Db At 31.25 Mhz
  • 65.6 Db At 62.5 Mhz
  • 65.6 Db At 100 Mhz
  • 58 Db At 200 Mhz
  • 56.5 Db At 250 Mhz
  • 55.3 Db At 300 Mhz
  • 53.5 Db At 400 Mhz
  • 52 Db At 500 Mhz
  • Near End Crosstalk [Next] : Guaranteed: 74.3 Db At 1 Mhz
  • Guaranteed: 65.3 Db At 4 Mhz
  • Guaranteed: 60.8 Db At 8 Mhz
  • Guaranteed: 59.3 Db At 10 Mhz
  • Guaranteed: 56.2 Db At 16 Mhz
  • Guaranteed: 54.8 Db At 20 Mhz
  • Guaranteed: 53.3 Db At 25 Mhz
  • Guaranteed: 51.9 Db At 31.25 Mhz
  • Guaranteed: 47.4 Db At 62.5 Mhz
  • Guaranteed: 44.3 Db At 100 Mhz
  • Guaranteed: 39.8 Db At 200 Mhz
  • Guaranteed: 38.3 Db At 250 Mhz
  • Guaranteed: 37.1 Db At 300 Mhz
  • Guaranteed: 35.3 Db At 400 Mhz
  • Guaranteed: 33.8 Db At 500 Mhz
  • Attenuation : Guaranteed: 2.1 Db @ 1 Mhz Per 100 M Cable
  • Guaranteed: 3.8 Db @ 4 Mhz Per 100 M Cable
  • Guaranteed: 5.3 Db @ 8 Mhz Per 100 M Cable
  • Guaranteed: 5.9 Db @ 10 Mhz Per 100 M Cable
  • Guaranteed: 7.5 Db @ 16 Mhz Per 100 M Cable
  • Guaranteed: 8.4 Db @ 20 Mhz Per 100 M Cable
  • Guaranteed: 9.4 Db @ 25 Mhz Per 100 M Cable
  • Guaranteed: 10.5 Db @ 31.25 Mhz Per 100 M Cable
  • Guaranteed: 15 Db @ 62.5 Mhz Per 100 M Cable
  • Guaranteed: 9.1 Db @ 100 Mhz Per 100 M Cable
  • Guaranteed: 27.6 Db @ 200 Mhz Per 100 M Cable
  • Guaranteed: 31.1 Db @ 250 Mhz Per 100 M Cable
  • Guaranteed: 34.3 Db @ 300 Mhz Per 100 M Cable
  • Guaranteed: 40.1 Db @ 400 Mhz Per 100 M Cable
  • Guaranteed: 45.3 Db @ 500 Mhz Per 100 M Cable
  • Standards : ISO/IEC 11801 Ea
  • ANSI/TIA-568-C.2
  • Cable Length : 305 M
  • Cable Outer Diameter : 7.3 mm
  • Power Sum Attenuation To Alien Crosstalk Ratio Far-End [Psaacrf] : 66.2 Db At 4 Mhz
  • 60.1 Db At 8 Mhz
  • 58.2 Db At 10 Mhz
  • 54.1 Db At 16 Mhz
  • 52.2 Db At 20 Mhz
  • 50.2 Db At 25 Mhz
  • 48.3 Db At 31.25 Mhz
  • 42.3 Db At 62.5 Mhz
  • 38.2 Db At 100 Mhz
  • 32.2 Db At 200 Mhz
  • 30.2 Db At 250 Mhz
  • 28.7 Db At 300 Mhz
  • 26.2 Db At 400 Mhz
  • 24.2 Db At 500 Mhz
  • Type Of Cable : 4 Pair Cables
  • Cable Shielding Type : F/Utp
  • Input Impedance : 100 Ohm (+/- 15 %) At 1-100 Mhz
  • 100 Ohm (+/- 22 %) At 100-250 Mhz
  • Maximum Loop Resistance : 72 Ohm
  • Flame Retardance : Cm
  • Cable Weight : 17 Kg
  • Awg Gauge : Awg 23
  • Capacitance Unbalance : 330 Pf / 100 M
  • Wire Insulation Material : Pe
  • Communication Network Category : 6A
  • Minimum Return Loss : Guaranteed: 20 Db At 1 Khz
  • Guaranteed: 23 Db At 4 Khz
  • Guaranteed: 24.5 Db At 8 Khz
  • Guaranteed: 25 Db At 10 Khz
  • Guaranteed: 25 Db At 16 Khz
  • Guaranteed: 25 Db At 20 Khz
  • Guaranteed: 24.3 Db At 25 Khz
  • Guaranteed: 23.6 Db At 31.25 Khz
  • Guaranteed: 21.5 Db At 62.5 Khz
  • Guaranteed: 20.1 Db At 100 Khz
  • Guaranteed: 18 Db At 200 Khz
  • Guaranteed: 17.3 Db At 250 Khz
  • Guaranteed: 16.8 Db At 300 Khz
  • Guaranteed: 15.9 Db At 400 Khz
  • Guaranteed: 15.2 Db At 500 Khz
  • Minimum sell quantity:

    Order Quantity Multiple:

    Technical Specifications

    Type Copper Cable
    Colour Blue